66 RXiIIIPlus User Guide 6/21/2004 23063L-001 Rev. 2
RFID Guidelines
^RS
Example 1 • This example sets the printer to move the media to 800 dots from the top of the
media [or label length minus 800 from the bottom (leading edge) of the media] and voids the
rest of the media in case of an error. The printer will try to print two labels, then will pause the
printer if printing and encoding fail.
^XA
^RS,800,,2,P^FS
^XZ
The following illustration shows the resulting voided label. Note where the void starts. The
media has been moved 800 dot rows from the top of the label (label length minus 800 dot rows
from the bottom (leading edge) of a label) to bring the transponder into the effective area to
read/write a tag. If the printer fails the operation, the rest of the media is voided.
Top of label
Start of RFID
operation
800 dot rows
Bottom of label
Label length minus
800 dot rows