Zebra XiII-Series Manual de usuario Pagina 103

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 118
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 102
RS-422/RS-485 Interconnections
The Zebra XiII printer may be connected to a host by either an RS-422 or
an RS-485 interface. The DB-25 connector on the rear of the printer uses
specific pins for this purpose. Figure 27 illustrates the required cable wiring
for interconnecting to the printer’s DB-25 connector. Figure 28 illustrates
the internal connections of the XiII printer’s RS-422 or RS-485 connector.
Zebra XiII-Series User’s Guide 91
Interconnecting
C
able
from Host RS-422/RS-485 Port
Male DB-25
to Printer
Figure 27. RS-422/RS-485 Interconnecting Cable
J3
RS-422/RS-485 Connector
Rear Panel DB-25S
Figure 28. RS-422/RS-485 Connections