Zebra 105SL Plus Guía de usuario Pagina 84

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 130
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 83
60 105SL User Guide 6/4/2004 11342L Rev. 8
Data Ports
Serial Data Port
Serial Data Port
The connection for this standard interface is made through the female DB-9 connector on the
rear panel. A DB-9 to DB-25 interface module is required for all RS-232 connections through
a DB-25 cable (see page 62 for details).
For all RS-232 input and output signals, the printer follows both the Electronics Industries
Association’s (EIA) RS-232 specifications and the Consultative Committee for International
Telegraph and Telephone (CCITT) V.24 standard signal level specifications.
Table 8 shows the pin configuration and function of the rear panel serial data connector on the
printer.
.
Table 8 • Serial Port Pin Configuration
Pin No. Name Description
1 Not connected
2 RXD Receive data—data input to printer
3 TXD Transmit data—data output from printer
4 DTR Data terminal ready—output from printer
5 SG Signal ground
6 DSR Data set ready—input to printer
7 RTS Request to send—output from printer
8 CTS Clear to send—input to printer
9 +5 V DC +5 VDC at 750 mA
The maximum current draw may be limited by option
configuration.
Note • An interface module is required for RS-422/RS-485 interface support (see page 63).