Maintenance
Fitting A Shutter
112
P1003636-001 TTP 7020™/TTP 7030™ Technical Manual 02/11/2009
Fitting A Shutter
Figure 28 • Fitting a Shutter
The shutter kit contains a shutter and two hub-screws. In addition to this, you need an 1.5 mm
Allen-key.
1. Fit one hub screw.
2. Hook the shutter onto the screw and insert the other screw, through the hole in the shutter
and into the thread in the printer.
3. Make sure the head of the screw goes into the hole of the shutter and then tighten it.
4. Verify that the shutter opens/closes as it should by printing a couple of documents.