RS-232 INTERFACE BAR CODES 2 - 3
RS-232 Host Parameters
Various RS-232 hosts use their own parameter default settings. Selecting standard, ICL, Fujitsu,
Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, Omron, Common Use Terminal
Equipment (CUTE-LP/LG bar code readers), NCR, or Datalogic sets the defaults listed in Table 2-2 and Table
2-3.
Table 2-2
Terminal Specific RS-232
Parameter ICL Fujitsu
Wincor-Nixdorf
Mode A
Wincor-Nixdorf Mode
B/OPOS/JPOS
Baud Rate
9600 9600 9600 9600
Parity
Even None Odd Odd
Stop Bit Select
One One One One
ASCII Format
8-Bit 8-Bit 8-Bit 8-Bit
Hardware Handshaking
RTS/CTS Option 3 None RTS/CTS Option 3 RTS/CTS Option 3
Software Handshaking
None None None None
Serial Response Timeout
9.9 Sec. 2 Sec. None None
RTS Line State
High Low Low Low = No data to send
Beep On <BEL>
Disable Disable Disable Disable
Transmit Code ID
Yes Yes Yes Yes
Data Transmission Format
Data/Suffix Data/Suffix Data/Suffix Data/Suffix
Prefix
None None None None
Suffix
CR (1013) CR (1013) CR (1013) CR (1013)
In the Wincor-Nixdorf Mode B, if CTS is low, scanning is disabled. When CTS is high, scanning is enabled.
If you scan Wincor-Nixdorf Mode B without connecting the digital scanner to the proper host, it may
appear unable to scan. If this happens, scan a different RS-232 host type within 5 seconds of cycling
power to the digital scanner.
Table 2-3
Terminal Specific RS-232
Parameter Olivetti Omron CUTE NCR Datalogic
Baud Rate
9600 9600 9600 9600 9600
Parity
Even None Even Odd Odd
Stop Bit Select
One One One One One
ASCII Format
7-Bit 8-Bit 7-Bit 7-Bit 7-Bit
Hardware Handshaking
None None None None None
Software Handshaking
ACK/NAK None None None None
The CUTE host disables all parameter scanning, including Set Defaults. If you
inadvertently select CUTE, scan Enable Parameter Bar Code Scanning (located in the
MP6000 Bar Code Programming Guide) then change the host selection.