60 Z4Mplus and Z6Mplus User Guide
Configuration
Configuration
Leave the Setup Mode
You can leave the program mode at any time by pressing SETUP/EXIT. The SAVE
CHANGES display appears. There are five choices, which are described below.
Pressing PLUS (+) or MINUS (–) displays other choices and pressing SELECT selects
the displayed choice.
PERMANENT — Permanently saves the changes. Values are stored in the printer
even when power is turned off.
TEMPORARY — Saves the changes until you change them again or until power is
turned off.
CANCEL — Cancels all changes from the time you pressed
SETUP/EXIT, except for darkness and tear-off settings (if they were changed).
LOAD DEFAULTS — Loads factory defaults.
LOAD LAST SAVE — Loads values from the last permanent save.
Press SETUP/EXIT again to save your choice.
Note • Once the password has been entered correctly, it does not have to be entered
again unless you leave and re-enter the programming mode using SETUP/EXIT.
Note • You can disable the password protection feature to no longer prompt you for
a password by setting the password to ØØØØ via the ^KPØ
ZPL/ZPL II command. To re-enable the password-protection feature, send the ZPL/
ZPL II command ^KPx, where x can be any number that is one to four digits in
length, except Ø.