^RS – RFID Setup
Use this command to set up RFID operation and error handling. You can
move the tag into an effective area to read or write.
The format for the ^RS instruction is:
^RSt,p,v,n,e
where the parameters are:
t = tag type
Default value: 1 –Auto Detect (automatically determine the
tag type, by querying the tag)
Other values:
2- Texas Instruments Tag-it™ tags
3- Philips I•Code tags
4- Inside Technologies Picotag® 2K
5- ISO 15693 tag (see note)
6- EPC Tag (13.56 MHz)
p = read/write position of a transponder in vertical (Y-axis) in
dot-rows from the top of the label.
Default value: label length minus eight dot-rows
Other values: zero to label length
Set to zero ( 0 ) so that the media will not move; that is, the
transponder is already in the effective area.
v = length of void print out in vertical (Y-axis) dot-rows.
Default value: label length
Other values: zero to label length
n = number of labels to try in case of read/encode failure
Default value: 3
Other values: 1 to 10, number of labels
e = error handling
Default value: 'N' (no action)
Other values:
'P'- printer pauses
'E'- printer goes into error mode
40 980476-001A