• 2-67 • RMAN-QLS-002 rev. A Repair Procedures
LabeL pReSence SenSoR, QL320- an16861-015
Tools Needed
#1 Phillips head screwdriver
3/32” Hex Driver
Remove the Upper Housing
1. Turn the printer off and remove the Battery.
2. Remove the QuickLink Module
3. Remove the Upper Housing, per AN16861-010
4. Open the Media Cover .
Assemble the Sensor Support
Snap the Sensor Support, or the Sensor Assembly into place on the Printer Frame as
shown. Note orientation of sensor widow. If you are installing a Label Presence Sensor
Assembly, proceed to the next step.
You must use an ESD strap and work at a properly grounded workstation (antistatic mat or tray).
All electronic components must be placed on an ESD protective tray. If stored, any elec-
tronic components must be placed in antistatic bags.
For QL 320:Support, Sensor
p/n CA16009-1 or
Label Presence Sensor Assy.
p/n AC16500-1M
For QL 320 Plus-: p/n CL16965-3, Cbl
Flex Crkt Shld Ql4 Lbl Sen,
is supplied with RK18465-003
Note orientation of sensor window