Mobile Printing Systems
CPCL Programming Manual
Section 10
Advanced
Utilities
pg. 10-7
continued
BAUD Utility
The BAUD command enables you to set the printer serial port baud rate.
Note: this command will take eect immediately and the requested baud rate will remain in eect when the printer is powered
down.
Format:
<!> <UTILITIES>
{command} {baud}
<PRINT>
Note that <PRINT> must be sent at the new baud rate
where:
{command}: BAUD
{baud}: Choose from the following:
1200
4800
9600
19200
38400
57600
115200
BAUD Example
Input:
! UTILITIES
BAUD 19200
PRINT