Vista de pagina 164
Mobile Printing Systems
CPCL Programming Manual
Section 10
Advanced
Utilities
pg. 10-16
continued
SET-TIME Utility
This command sets the time in the real time clock module. Time should be a valid time and be given
in the specified format. This command will be ignored by printers that are not equipped with a real time
clock module.
Format:
<!> <UTILITIES>
{command} {time-stamp}
<PRINT>
where:
{command}: SET-TIME
{time-stamp}: hh:mm:ss
hh = hours (00 – 23)
mm = minutes (00 – 59)
ss = seconds (00 – 59)