59
ZPL Basics
The ZPL Format (Receipt Form or Template)
10/29/2010 Software Integrator Guide P1026208-001 Rev. B
From this point in the Configuration Receipt listing, the printout has sensor settings and
values are displayed to troubleshoot sensor and media operations. These are typically
used by Zebra Tech Support to diagnose printer problems.
^KV,b
CUT MARGIN Default: 009 (9 mm Range:2-9)
^KV,,c
PRESENT TYPE Default: EJECT (0)
^KV,,,,e
LOOP LENGTH Default: 400 (400 mm Range: 3- 1023 mm)
SGD CMD
ORIENTATION Default: HORIZONTAL
^MN
MEDIA TYPE Default: VARIABLE LENGTH
—
SENSOR TYPE MARK (The KR403 only has mark sensing)
—
SENSOR SELECT MANUAL (^MNM must be set to calibrate
to black mark/line media)
^PW
PRINT WIDTH Default: Uses Media Guide to determine
width
^LL
LABLE LENGTH Default: 1225 (dots)
^ML
MAXIMUM. LENGTH Default: 24.0IN 609MM
—
USB COMM. Connection Status: Connected / Not
Connected
^SCa
BAUD Default: 11520
^SC,,c
DATA BITS Default: 8
^SC,,,d
PARITY Default: NONE
^SC,,,,e
HOST HANDSHAKE Default: 1225
^SC,,,,,f
PROTOCOL Default: <
^CT / ~CT
CONTROL CHAR Default: <~> 7EH
^CC / ~CC
COMMAND CHAR Default: <^> 5EH
^CD / ~CD
DELIM.CHAR Default: <,> 2CH
^SZ
ZPL MODE Default: ZPL II (Do Not Change!!)
^MFa
MEDIA POWER UP Default: NO MOTION
^MF,b
HEAD CLOSE Default: CALIBRATION
~JS
BACKFEED Default: BEFORE
^LT
LABEL TOP Default: +000
^LS
LEFT POSITION Default: +0000
~JD / ~JE
HEXDUMP Default: NO (~JE)
Table 5-4 • ZPL Commands and Configuration Receipt Callout Cross-Reference