Routine Maintenance
Cleaning Procedures
1/11/11 Z Series
®
/RZ™ Series User Guide 79695L-003
4. See Figure 17. Using the swab from the Preventive Maintenance Kit (part number 47362),
wipe along the upper cutting surface (
1) and the cutter blade (2). In place of the
Preventive Maintenance Kit, you may use a clean swab dipped in a solution of isopropyl
alcohol (minimum 90%) and deionized water (maximum 10%). Allow the solvent to
evaporate.
Figure 17 • Cleaning the Cutter Module
5. Replace the cutter shield.
6. Plug the printer into its power source, and then turn on (I) the printer.
The lower cutter blade returns to its correct operating position.
7. If the cutter continues to perform unsatisfactorily, contact an authorized service
technician.