is useful if a card has been encoded with an equipment that does not
follow the ISO standards, or by a TTPM2 by the use of command !N.
•
A separate version of the TTPM2 software, numbered 926-xxx, is
introduced. This version is used with TTPM2 equipped with CD200 card
dispenser.
•
A minor correction has been made to the routine used to enter variables.
The correction eliminates a problem when users are sending empty lines,
too many lines, or both, in relation to the number of defined variable
parameters.
906/907-220
•
Encoding of the 210 bpi track 1 can now be done in ISO 7811 format. The
new command !J + data defines the data to be encoded on track 1. Valid
characters are ASCII space (20H) through to ASCII (5FH). Start, stop and
checksum are automatically added by the TTPM2.
•
The !D command has been given the extension !D1 defined so that a card
encoded with !J can be read in the TTPM2.
•
If the digit 1 is left out, the !D command will read track 2 as usual. No
modification is therefore necessary for customers using the old !D
function.
906/907-221
Correction of a bug in the !D1 routine causing reading to fail if the routine is not
the first operation after a reset.
906/907-222
•
A new command !L5 has been implemented. The command ejects a
ticket forwards into the "waste bin". This is useful if the system decides to
cancel a ticket. Only valid for printers with the optional front load
function.
•
It is also possible to direct striped and voided tickets to the waste bin by
including an @ character in the !M string.
•
The 24 V power supply relay is now being switched off after
approximately 30 s of inactivity.
906/907-228
•
This version includes support for bar code 39. If a bar code is selected,
the print speed will be reduced in order to maintain the print quality.
906/907-229
•
All versions of this FW release now include the command !I that correctly
en-codes track 3 according to the ISO 7811 format. Reading can be done
with command !D 3.
•
Firmware 907 (dual tracks): Handling has been modified slightly to
prevent paper jam. It is also possible to use the printer with only one of
the tracks loaded with paper. The self-test, however, uses only the lower
input.
906-230
•
This version is only released for firmware 906 (dual ticket tracks).
Corrects a bug that caused the printer ignore the single ticket entry if the
24 V relay had been shut off.
906/907-231
•
New version of the dual fanfold ticket entry printer.
•
In order to increase the flexibility, two new subcommands have been
added to the !L command:
- !L17 Loads the lower track into active position. - !L18 Loads the
upper track into active position.