ZPL Commands
~SD
252
45541L-004 Rev. A ZPL II Programming Guide 9/15/06
~SD
Set Darkness
Description The ~SD command allows you to set the darkness of printing. ~SD is the
equivalent of the darkness setting parameter on the control panel display.
Format ~SD##
This table identifies the parameters for this format:
Comments The
^MD command value, if applicable, is added to the ~SD command.
Parameters Details
## = desired
darkness setting
(two-digit
number)
Accepted Values:
00 to 30
Default Value: last permanently saved value
Example • These are examples of the XiIIIPlus Darkness Setting:
^MD8.3
~SD8.3