RFID Commands
^HR
290
45541L-004 Rev. A ZPL II Programming Guide 9/15/06
Comments
Based on the recommended transponder placement position for most RFID labels, the
printer’s default RFID programming position is zero for the R110PA X4. For other RFID
printers, the default programming position is the label length minus 1 mm (0.04 in.).
To return to the default programming position at any time, use the RESTORE option in the
RFID TAG CALIB control panel parameter.
At the end of calibration, a results table is returned to the host. Each line in the results
table appears as:
Row, Read Result, Write Result
where
Row = the dot row where calibration occurred
Read Result = results of calibration (R = read, “ ” = unable to read)
Write Result = results of calibration (W = write, “ ” = unable to write)