32056L Rev. 2 12/4/01 105SL Maintenance Manual Page 4-53
PREVENTIVE AND CORRECTIVE MAINTENANCE SECTION 4
10. Reconnect the power cable to the power source. Place the power switch in the On (I)
position.
$&3RZHU)XVH5HSODFHPHQW
The 105SL printer uses a metric-style fuse, 5 x 20 mm IEC, rated at F5A, 250V. The end caps
of the fuse must bear the certification mark of a known international safety organization as
shown in Figure 4-40.
3ULQWHU&RQILJXUDWLRQV;;;;;;;DQG;;;;;;;
The AC power entry module comes with two approved fuses in the fuse holder: one is “In-
Circuit” and the second is provided as a “spare”. Refer to Figure 4-41.
Figure 4-39. Media Supply Hanger Installation
Figure 4-40. International Safety Organizations