Zebra 105SL Especificaciones Pagina 242

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 246
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 241
Page 6-28 105SL Maintenance Manual 32056L Rev. 2 12/4/01
SECTION 6 OPTION KITS
Figure 6-23. Twinax Connections
Table 6-5. Twinax Dip Switch Setting
Print complete
Switch #1 Description
Left An “Operation Complete” status message is sent to the host after a label format is completely
printed. The host can then send the next label format to be printed.
Right Enables the “Early Print Complete” function. The host can send additional print jobs to the Zebra
printer without waiting for the actual completion of the current print job. The printing status sent
to the host reflects the label formats received, not the ones completed.
EBCDIC Buffer Print
Switch #2 Description
Left Normal operation (received EBCDIC data is translated to ASCII Data).
Right Received EBCDIC data prints as large characters that are readable hex equivalents. Use only
for troubleshooting with the printer in the “Diagnostics” mode
Printer Emulation Selections
Switch #3 Switch 4 IBM Printer Configured
Left Left 5256 Model 3
Left Right 5225 Model 4
Right Left 5224 Model 2
Right Right 4212 Model 2
Default Language Selections
Switch #5 Switch 6 Switch 7 Switch 8 Language Selected
Left Left Left Left 0 -Multinational
Left Left Left Right 1 - USA/Canada (Factory setting)
Left Left Right Left 2 - Austria/Germany
Left Left Right Right 3 - Belgium
Left Right Left Left 4 - Brazil
Vista de pagina 241
1 2 ... 237 238 239 240 241 242 243 244 245 246

Comentarios a estos manuales

Sin comentarios