Zebra 96XiIII Plus Guía de usuario Pagina 178

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 230
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 177
Data Ports
Serial Data Port
178
13383L-004 Rev. A XiIIIPlus/R110Xi/R170Xi User Guide 9/6/07
RS-232 Interface Connections
The printer is configured as Data Terminal Equipment (DTE). Figure 38 shows the internal
connections of the printer’s RS-232 connector.
Figure 38 • RS-232 DB9 MLB Connections
Pin 9 is also available as a +5 VDC signal source at 750 mA. The maximum current draw may
be limited by option configuration.
Note • Use a null modem (crossover) cable to connect the printer to a computer or any other
DTE device.
Important • To enable this capability, a qualified service technician must install a jumper on
the printer’s main logic board on JP1, pins 2 and 3.
NOTE: Pin 1 is unused and unterminated.
RS-232 Connector (DTE)
Rear Panel Female DB-9
RXD (receive data) input
TXD (transmit data) output
DTR (data terminal ready) output
SG (signal ground)
DSR (data set ready) input
RTS (request to send) output
CTS (clear to send) input
+5 VDC signal source
2
3
4
5
6
7
8
9
R1
+5 VDC
1K
Vista de pagina 177