Zebra S4M Especificaciones Pagina 306

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 404
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 305
Preventive and Corrective Maintenance
Main Logic Board
282
13291L-001 Rev. A S4M Maintenance Manual 10/27/05
Remove the Old Main Logic Board
1.
Connect yourself to an antistatic device.
2. See RRP No. 1 on page 122 and remove the electronics cover.
3. See Figure 151. Remove all cables from the main logic board.
Figure 151 • Remove the Main Logic Board Connections
Caution • Observe proper electrostatic safety precautions when handling
static-sensitive components such as circuit boards and printheads.
Note • Take note of the location of all connectors on the main logic board.
1
Printhead data (J3)
7
Transmissive sensor (P9)
2
Power-in (J8)
8
Reflective sensor (P7)
3
Front panel (J2)
9
Take-label sensor (J19)
4
Stepper motor (j9)
10
Communication expansion
port (J17)
5
Booster board (J7)
11
USB port (J14)
6
Ribbon sensor, head open
sensor (P4)
12
Serial port (J10)
F6
L
F
1A
1
2
3
4
5
6
7
8
10
11
12
9
Vista de pagina 305