Operations
Control Panel LCD Display
72
13291L-001 Rev. A S4M Maintenance Manual 10/27/05
TAKE LABEL
Adjust the Peel Sensor
This parameter appears only if the Peel option is installed.
Range: 0 to 100
Default Value: 66
To modify this parameter:
• To increase the value, press the up arrow.
• To decrease the value, press the down arrow.
MEDIA POWER UP
Select Media Power-Up Option
This parameter sets the action of the media when you turn on the printer.
Selections: CALIBRATION, LENGTH, SHORT CAL, NO MOTION,
FEED
Default Value: CALIBRATION
• Calibration—determines the length of the label and adjusts the
sensor settings.
• Length—In continuous mode, feeds the last stored label length. In
noncontinuous mode, calibrates based on the maximum label length
setting (see Set Maximum Label Length on page 58).
• Short Cal—calibrates label length using the current sensor settings.
• No Motion—the media does not move. Press
FEED to cause the
printer to resynchronize to the start of the next label.
• Feed—feeds the labels to the first registration point.
To modify this parameter:
• Press the up or down arrow to display other choices.
HEAD CLOSE
Select Head Close Option
This parameter sets the action of the media when you close the printhead.
Selections: CALIBRATION, LENGTH, SHORT CAL, NO MOTION,
FEED
Default Value: CALIBRATION
• Calibration—determines the length of the label and adjusts the
sensor settings.
• Length—In continuous mode, feeds the last stored label length. In
noncontinuous mode, calibrates based on the maximum label length
setting (see Set Maximum Label Length on page 58).
• Short Cal—calibrates label length using the current sensor settings.
• No Motion—the media does not move. Press
FEED to cause the
printer to resynchronize to the start of the next label.
• Feed—feeds the labels to the first registration point.
To modify this parameter:
• Press the up or down arrow to display other choices.