43
Operations
Select or Adjust the Media Sensors
10/27/05 S4M Maintenance Manual 13291L-001 Rev. A
Figure 21 • Adjusting the Reflective Sensor
To adjust the reflective sensor, complete these steps:
1. See Figure 21. Press the printhead release latch.
2. Lift the printhead until it latches open.
3. Locate the reflective sensor positioning lever.
4. Move the reflective sensor positioning lever across the width of the media until the
reflective sensor aligns with the gap or notch.
5. Close the printhead assembly.
1
Printhead assembly
2
Reflective sensor
3
Reflective sensor positioning lever
4
Printhead release latch
1
2
3
4