318
Chapter 6 Restore The Printer To Operation
33 HEAD OPEN
TIMEOUT
Yes Status message in the
CT emulation: The
printer was offline more
than 10 minutes, and
the "Intervention
Required" parameter is
set to "Send to Host."
Close and latch the printhead.
Press PAUSE to put the printer
online.
40V POWER FAIL Yes +40 VDC: an internal
power failure.
Power off the printer for 15
seconds, then power back on.
If the problem persists, contact
your authorized customer
service representative.
203 DPI Head
Installed
Yes Normal power-up
message. The printer
is running its
initialization routine
and indicating DPI
resolution of the
installed printhead.
No action required.
300 DPI Head
Installed
Yes Normal power-up
message. The printer
is running its
initialization routine
and indicating DPI
resolution of the
installed printhead.
No action required.
Ambient light
Validator failure
Yes Ambient light is
compromising proper
scanning.
NOTE: The Validator
scanning laser cannot
work properly in a
room with excessive
ambient light, including
direct sunlight.
1. Minimize the ambient light
around the validator. This
may require moving the
printer to a darker area of
the room.
2. Press the PAUSE key to
clear the fault message.
BAD VFU CHANNEL Yes The user tried to use
an undefined VFU
channel.
Use defined channels.
BAR CODE
IMPROPER
Data Format
Yes Data validation error:
improper data format.
Fix application so it sends data
in the correct bar code format.
Table 17. LCD Message Troubleshooting (continued)
Displayed Message
Can User
Correct?
Explanation Solution
Comentarios a estos manuales