Zebra MP6000 Especificaciones Pagina 136

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 210
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 135
4 - 6 MP6000 INTEGRATOR GUIDE
a. Place 25 lb weights on the scanner as shown in Figure 4-2; three 5 lb weights centered on the center
of the scale, and two 5 lb weights centered on top.
Figure 4-2
Weight Calibration Configuration for Pounds
b. Place 11 kg weights on the scanner as shown in Figure 4-3; two 5 kg weights centered on the center of
the scale, and one 1 kg weight on top between the two 5 kg weights.
Figure 4-3
Weight Calibration Configuration for Kilograms
2. Press the Scale Zero button with the weights on the platter.
3. Calibration continues with Step 5 - Calibration Success or Failure on page 4-7. Calibration was either
successful or failed at this step.
Center of Scale
Center of Scale
Vista de pagina 135
1 2 ... 131 132 133 134 135 136 137 138 139 140 141 ... 209 210

Comentarios a estos manuales

Sin comentarios