5 - 20 MP6000 INTEGRATOR GUIDE
Beeper and LED Conditions
NOTE Refer to the MX101 Product Reference Guide (p/n 72E-171320-xx) for beeper and LED conditions for the
CSS device.
Table 5-1
Beeper and LED Indicators
Condition Beeper Indication
System LED
Indication
Button LED
Indication
Description
ADF Programming
Number expected High, Low Beeps Green No change Enter another digit. Add leading
zeros to the front if necessary.
Alpha character
exp
ected
Low, Low Beeps Green No change Enter another alphabetic character
or scan the End of Message bar
code.
Criteria or action
exp
ected
High, High Beeps Green Blinking No change ADF criteria or action is expected.
Enter another criterion or action, or
scan the Save Rule bar code.
ADF rule saved High, Low, High, Low
Bee
ps
Green (turns off
blinking)
No change Rule saved. Rule entry mode
exited.
Criteria or action
clea
red
High, Low, Low Beeps Green No change All criteria or actions cleared for
current rule, continue entering rule.
Last rule deleted Low Beep Green No change Delete last saved rule. The current
rule is
left intact.
All rules deleted Low, High, High Beeps Green No change All rules are deleted.
ADF out of
me
mory
Low, High, Low, High
Beeps
Red No change Out of rule memory. Erase some
existing rules, then try to save rule
again
Cancel rule entry Low, High, Low Beeps Green (turns off
blinking)
No change Cancel rule entry. Rule entry mode
ex
ited because of an error or the
user asked to exit rule entry.
Rule error Low, High Beeps Red No change Entry error, wrong bar code
sc
anned, or criteria/action list is too
long for a rule. Re-enter criterion or
action.
Button Presses
Press and release
Scale Zero
button
Click No change
Scale Zero
button LED
blinks green
(momentary)
LED illuminates only if
Scale Zero
button is enabled. Causes the
scale to zero.
Comentarios a estos manuales