2 - 4 MP6000 INTEGRATOR GUIDE
Connecting a USB Interface
The MP6000 connects directly to a USB host. An additional power supply may be required
(PWRS-14000-148R). Only a USB Power Plus host can power the MP6000 using a Zebra Power Plus cable,
without an external power supply.
Figure 2-1
USB Connections
There are three possible USB connection methods for the MP6000:
•
POS connection using USB Power Plus (12V); requires a CBA-U52-S16PAR cable between POS
equipment (e.g., IBM) and the MP6000 POS RJ-45 connector. The MP6000 is a USB device for this
connection; no power supply is required (the MP6000 draws power from USB cable).
•
POS connection using USB Standard A (5V); requires a CBA-U51-S16ZAR cable between POS
equipment (standard device - PC) and MP6000 POS RJ-45 connector. The MP6000 is USB device but
requires an external power supply (MP6000 does NOT draw power from USB cable).
•
AUX scanner connection using a Zebra USB hand-held scanner; requires a Zebra USB type A cable
between the Zebra USB hand-held scanner (RJ-45), and the MP6000 AUX A-B USB port. The MP6000
is the USB host, and the Zebra scanner is the USB device which draws power from 5V cable.
NOTE For a list of supported scanner functionality by communication protocol Appendix E, COMMUNICATION
PROTOCOLS.
NOTE Interface cables vary depending on configuration.