OPERATING THE SCANNER 5 - 17
Electronic Article Surveillance (EAS)
The MP6000 has integrated Electronic Article Surveillance (EAS) options which allow support for Sensormatic
EAS controllers or Checkpoint EAS controllers. (See EAS Devices on page 1-8 for supported EAS controllers.)
The MP6000 and EAS system can operate
independently of each other, or using communication cable to
synchronize deactivation with barcode scanning. The deactivation range is mapped suitable to the scanner
range, so both can be accomplished almost simultaneously
Supported EAS Controllers
Sensormatic
Sensormatic ScanMax-Pro
Sen
sormatic AMB-9010 (available December 2014)
Checkpoint
Ch
eckpoint Interlocked, requires interlock cable: CB000002A01
Checkpoint Non-Interlocked.
EAS Operating Modes and Settings
EAS operating modes function when EAS is enabled at the site and are independent of whether or not EAS
equipment is connected. It is the installer's responsibility to match these settings with the installed equipment.
Enabling EAS without EAS equipment, or with the wrong equipment installed, displays an EAS error message.
See Beeper and LED Indicators on page 5-20 and Diagnostic LED 7-segment Display - Error and Warning
Codes on page A-2 for beeper, warning, and error mess
ages. Also refer to the MP6000 Bar Code
Programming Guide (p/n
72E-172633-xx) for EAS bar codes.
The default mode for EAS
is disabled. Disable EAS when this technology is not used, or if you are using
Checkpoint without interlock.
There are 10 EAS operating modes and
various EAS preferences for the MP6000:
Sensormatic Auto
Sensormatic Always Enabled
Sensormatic Bar Code Interlock
Sensormatic Bar Code Auto Interlock
Sensormatic Self Service
Sensormatic Scan Enable Interlock
Checkpoint Bar Code Interlock
Checkpoint Scan Enable Interlock
Checkpoint Non Bar Code Interlock
EAS Disable.
NOTE Checkpoint and Sensormatic EAS systems require proper installation by representatives from those
companies who install, verify, and tune the system for proper EAS operation. This is typically done on-site
by those companies.