Zebra TTPM3 Especificaciones Pagina 44

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 112
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 43
Programming
Command Reference
43
P1003642-001 TTPM3 Installation and Programming Manual 01/06/2009
The burn time controls the print density. It is used to set the heating so that it is adequate for
the thermal paper used as ticket material. Set it to the lowest burn time that gives acceptable
print quality.
The burn time setting is stored in the non-volatile memory.
Power off/on reset returns the setting to default value.
The TTPM3 responds by sending the same 1 byte response to the host computer as is sent as
byte 1 in response to the !S command. The ENQ command is effected immediately after
receipt, whereas the !S command is effected in sequence when received.
!Z
Set burn time
21 5A Hex
33 90 Decimal
Setting Burn time Print Density
16 512 μs Lightest print
17 544 μs
18 576 μs
19 608 μs
20 640 μsDefault
21 672 μs
22 704 μs
23 736 μs
24 768 μs
25 800 μs
26 832 μs
27 864 μs
28 896 μs
29 928 μs
30 960 μs
31 992 μs Darkest print
Example • This example sets the burn time to 640 μs.
!Z 20 <CR><LF>
Caution • A longer burn time puts more load on the printhead, so do not use a longer burn
time than required for a clearly legible print. Settings over 27 are not recommended.
ENQ
Status request, immediate
05 Hex
05 Decimal