Programming
Command Reference
65
P1003642-001 TTPM3 Installation and Programming Manual 01/06/2009
Parameter number 255 contains a checksum calculated as the sum of all parameters from
parameter 1 to the parameter number given by parameter 0.
A utility program for loading firmware is available on the Zebra web site (The TTP Editor). If
you want to make remote upgrading of firmware possible though your ticketing system you
should implement the !H F command.
After burning the new firmware into the Flash PROM, the printer will make a reset.
Example 1 • Recalls the setting of parameter 1 (baudrate).
!S P 1 1<CR><LF>
Example 2 • Recalls the setting of parameter 1 to 4.
!S P 1 4<CR><LF>
Example 3 • Recalls the setting of all parameters.
!S P<CR><LF>
Example 4 • Parameter number 0 reflects the No. of parameters stored in the printer. So If
you send !S P 0 1 to the printer and get a 14 as reply you know that there are 14 parameters
that you can read out.
!S P 0 1<CR><LF>
!H F
Load firmware
21 48 20 53 Hex
33 72 32 83 decimal
Example 1 • Prepares the printer for incoming data.
!C<CR><LF>
Example 2 • Tells the printer that the binary to come is a firmware file.
!H F<CR><LF>
Example 3 • Here you should have a delay of 100 ms before sending the firmware file to the
printer port.
Delay 100 ms
Example 4 • Firmware file with the version you intend to upgrade to.
Binary file