Sets the speed at which the stepper motor starts to accelerate. Normally you never have to
change this setting.
10=100 steps/s
…
30=300 steps/second
300 steps/s gives 30 mm/s
!H P 10 40
Sets 400 steps/second
1=1000 steps/s
…
450=4500 steps/second
1000 steps/s gives 100 mm/s
!H P 11 400
Sets 4000 steps/second
Sets the speed at which the stepper motor starts to accelerate. Normally you never have to
change this setting.
10=100 steps/s
…
160=1600 steps/second
With normal resolution, 1000 steps/s gives 50 mm/s
!H P 12 100
Sets 1000 steps/second
10
30 Default
Encoding start speed
0 Min
999 Max
Note • Some settings result in printer chassis resonance causing increased noise and
deteriorated print quality.
11
450 Default
Encoding full speed
1 Min
999 Max
Note • Some settings result in printer chassis resonance causing increased noise and
deteriorated print quality.
Note • When long tickets are used the encoding speed must be reduced to 350.
12
100 Default
Print start speed
0 Min
999 Max
Note • Some settings result in printer chassis resonance causing increased noise and
deteriorated print quality.