61
Printer Maintenance
On-Site Service Cleaning
12/23/2009 KR403 Integrators Guide P1016701-001
5. Clean all the all of the feed and drive rollers with a fiber-free swab (such as a Texpad
swab) lightly moistened with medical grade alcohol (90% pure or better). Rotate the
rollers with your fingers to expose all of the roller’s surface. Slide a swab into the media
retract slot and clean the spring
6. Clean all the sensors with a fiber-free swab (such as a Cleaning swabs - p/n 105909-057)
lightly moistened with medical grade alcohol (90% pure or better). Use the aerosol can of
compressed air to dry the sensor. You may have to do this several times until all residue of
foreign material (smoke tar, grease, adhesive) has been cleared. One or two times may
only dilute or thin out residue. See the procedure for Dust Removal Cleaning on page 56
for the location of all the sensors that need cleaning.
7. Replace the Present and In Retract Roller assemblies.
8. Clean the printhead. See Cleaning the Printhead on page 42.