Vista de pagina 27
RMAN-RWS-001 rev. B • RW Series Repair Procedures • 2-28 •
4 Plug in the Printhead, Bar Sensor and the Gap Sensor Cable to the CPU Board
per the table below. If you unplugged the Motor cable, plug it into J6 at this
time.
CPU CONNECTIONS
CABLE CPU CONNECTOR
MOTOR CABLE J6
BAR SENSOR FLEX CABLE J2
GAP SENSOR FLEX CABLE J10
PRINTHEAD CABLE J5
5. Re-secure the CPU Board. Refer to Procedure RK17393-020 for more details.
6. Install the Upper Housing Assembly. Refer to Procedure RK17393-008 /
RK18280-1 for more details. Also ensure you have re-installed the D-Rings
between the Upper and Lower Housings.
7. Install the Battery Pack and media and perform a two-key reset to verify that
the Printhead has been properly installed.
8. Perform the Unit Test procedure. Perform a complete unit test to ensure that
the sensor calibrations are still correct.
Thecalibrationprocedurecanonlybeperformedbycertiedpersonnelusing
special equipment and software.
Bar, Spring
Replacement Printhead
Springs (2)
p/n BA17087-1
(Included with RK17393-005)