Page 4-48 Z4M/Z6M Maintenance Manual 77259L Rev. 4 12/16/03
6HFWLRQ 3UHYHQWLYHDQG&RUUHFWLYH0DLQWHQDQFH
.
Figure 4-39. Media Sensor Removal
,QVWDOO0HGLD6HQVRU$VVHPEO\
1. Refer to Figure 4-39. Install the new media sensor assembly into the carrier by
snapping the sensor portion into the carrier. Ensure that the button, spring and
insulator have the proper spring action by pressing down on the button and releasing
it.
2. Route the media sensor wires through the wireway on the platen roller assembly and
through the access hole in the printer frame. Replace cable ties that have been
previously cut. Connect the media sensor connector to the main logic board at P6.
3. Start the media sensor carrier through the slots provided on the platen roller
assembly. Gently press down on the media sensor carrier and push the carrier past
the stop.
4. Release the carrier and push it back and forth to make sure it travels its entire route
on the platen housing tracks. Reinstall the platen assembly latch cover.
5. Install the electronics cover. Replace media and ribbon in the printer and close the
media door. Reconnect power cord to the printer.
6. Turn the printer On (l) and print a configuration label using the Cancel Key Self
Test.
Platen Roller
Assembly
Media Sensor
Assembly
Media Sensor
Carrier
Media Sensor Holder
Mounting Tabs
Latch Cover
Note • Make sure to loop the wire harness inside the platen roller assembly
wireway. There should be no twists in the wire harness in the wireway. Ensure
that the media sensor assembly can travel its entire route.