77259L Rev. 4 12/16/03 Z4M/Z6M Maintenance Manual Page 2-23
2SHUDWLRQV2YHUYLHZ 6HFWLRQ
0HGLDDQG0HGLD6HQVRU&RQVLGHUDWLRQV
It is important that the appropriate media sensor is selected for the type media being used.
If the Transmissive Sensor is set to Auto Select mode and an auto-calibration condition
occurs (see media calibration), the appropriate media sensor will be selected. If Sensor
Select is set for Reflective Sensor or Transmissive Sensor, the auto-calibration will
calibrate the selected Media Sensor and ignore the other.
The trade-off between using Auto Select instead of the Reflective Sensor or Transmissive
Sensor is an increased time to print the first label. If the Sensor Select is set for Reflective
Sensor or Transmissive Sensor, the autocalibration will take longer to complete because it
is determining which media sensor to activate.
Reflective sensor type media – Non-continuous (labels, notched tags) media
This type of media has some type of physical characteristic (notch, black mark, gap
between die-cut labels etc.) which indicates the start-of-label position. The reflective
sensor must be properly positioned to sense these indicators.
Transmissive sensor type media – Pre-printer liners, thick and opaque liners or
dark adhesive sided media
This type of media requires the use of the transmissive sensor. The reflective sensor will
not properly calibrate with this type of media.
$XWR&DOLEUDWH
The autocalibration of the Z4M/Z6M printer occurs at power-on and each time the printer
recovers from error conditions such as media errors, ribbon errors and printhead open
errors. When clearing an error, open and close the printhead and take the printer out of
pause. The printer will begin the autocalibration process if all errors have been cleared.
During autocalibration, the printer automatically determines the label length, media and
ribbon sensor settings. When non-continuous media is sensed, the calibration process is
followed by the label length calculation. Once the label length is determined, the media
feeds to the rest position and stops.
The results of this calibration are stored in the printers memory and retained even if
printer power is removed. These parameters remain in effect until the next calibration is
performed.
&DOLEUDWH&RQWURO
The autocalibration process will not take place if the ZPL command or the front panel
setting for “Media Power Up” or “Head Close” is set to “no motion.” If set to “feed” the
printer will feed until the first sensed gap, notch or mark passes the tear off bar. In these
cases, the printer assumes the media is correctly positioned and starts printing without
calibrating.
As long as the printhead is closed, calibration may be performed. Calibration may clear
error conditions that prevent media movement. Unless an out-of-ribbon or out-of-media
condition exists, ribbon and media error conditions are cleared by calibration.