Zebra Z6M Especificaciones Pagina 70

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 168
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 69
Page 4-10 Z4M/Z6M Maintenance Manual 77259L Rev. 4 12/16/03
6HFWLRQ 3UHYHQWLYHDQG&RUUHFWLYH0DLQWHQDQFH
&RUUHFWLYH0DLQWHQDQFH
Corrective maintenance consists of the following:
Troubleshooting printer faults to a modular level.
Replacing or adjusting faulty or inoperable components.
Returning the printer to proper operating condition.
7RRO V5HTXLUHG
Standard Screwdrivers
Phillips Screwdrivers
Metric Hex Key (Allen wrench) Set
Standard Hex Key (Allen wrench) Set
Metric Nut Driver Set
Standard Nut Driver Set
Long Needle Nose Pliers
Anti-static wrist strap and mat (Portable Field Service Kit) (used for handling
electronic components)
Isopropyl Alcohol (90% alcohol/10% de-ionized water)
Cotton Swabs and lint free cloths
0.060 inch Feeler Gauge or shim
small (4-inch) crescent wrench
small punch
3ULQW0HFKDQLVP5HSODFHPHQW
5HPRYH3ULQW0HFKDQLVP
1. Turn the printer power Off (O) and disconnect the AC power cord.
2. Refer to Figure 4-4. Open the media door and remove media and ribbon from the
printer.
3. Remove the electronics cover by removing one or two screws securing the cover.
Caution • This installation must be performed by a qualified service technician.
Caution • Observe proper electrostatic safety precautions when handling any
static-sensitive components such as circuit boards and printheads.